當前位置:首 頁 ? News ? Company News ? How to calibrate electronic sphygmomanometer

How to calibrate electronic sphygmomanometer

文章來源:鑫志科技 / 作者:鑫志科技 / 發表時間:2021-10-19

The electronic sphygmomanometer, like the mercury sphygmomanometer, needs to be calibrated regularly. It is necessary to ensure calibration at least once a year to ensure the normal measurement data.

First, according to the standard operating instructions, the mercury sphygmomanometer without defects and the right upper arm can be respectively placed on the left upper arm, and the suspected accuracy of the electronic sphygmomanometer can be placed on the left upper arm. Naturally, the sphygmomanometer on both sides will stop inflation testing synchronously. After the blood pressure starts the electronic sphygmomanometer switch, stop the pressure measurement of the mercury sphygmomanometer immediately, measure continuously for 2 to 3 times, and take the uniform value, The uniform value of bilateral readings is the standard reading of two sphygmomanometer, and the mercury sphygmomanometer reading is the accurate blood pressure. The difference between the two standard readings is the bias of the electronic sphygmomanometer suspected of accuracy.

Second, first measure blood pressure with mercury column sphygmomanometer; After three minutes of rest, measure the blood pressure with an electronic sphygmomanometer for the second time; Then rest for three minutes, and measure the blood pressure for the third time with a mercury column sphygmomanometer; Take the uniform value of the first and third measurements. Compared with the value measured by the electronic sphygmomanometer for the second time, the difference should generally be less than 5 mm Hg. If it is not correct, then the electronic sphygmomanometer needs calibration. The most scientific calibration method is to take the electronic sphygmomanometer to the quality monitoring department for calibration once a year.

Factors affecting the accuracy of measurement results of electronic sphygmomanometer

1. The first generation of mechanical constant speed exhaust valves were often considered imprecise due to the use of rubber valves that were prone to aging; This technology has been eliminated by mainstream electronic sphygmomanometer manufacturers;

2. The software of electronic sphygmomanometer from different manufacturers is complete and different, and the stability and accuracy of measurement results are also far from each other;

3. Not calibrated or not calibrated regularly;

4. Improper application method: The correct application method is to adhere to the position of the cuff or wrist strap at the same level as the heart during the testing process, and also adhere to not speaking, sitting upright, and maintaining a stable mood;

5. Inappropriate use of people or places. Generally speaking, pay attention to the purchase of a good brand of electronic sphygmomanometer, and pay attention to the above points, then the measurement results of electronic sphygmomanometer still have some reference value.

咨詢

QQ

在線客服

服務時間:9:00-18:00

電話

服務咨詢熱線:

0755-2780-8770

微信

二維碼

微信咨詢

郵箱

電子郵箱

xuzb@xzkj.net.cn

主站蜘蛛池模板: 2024亚洲欧美国产日韩| 久久精品国产清高在天天线| 久久久久国产精品无套专区| 精品久久亚洲| 国产精品有码av| 丰满人妻熟妇乱精品视频| 国产AV亚洲AV麻豆专区| a片日韩美女视频免费| 久久无码AV亚洲精品色午夜麻豆| 毛片官网| 欧美亚洲国产人成aaa| 亚洲mv大片免费网站| 国产AV亚洲精品无码专区| 岛国大片在线免费观看 | 无码插插高潮| 高清性色生活片免费播放网| 国产一区麻豆精品一区| 国产真实乱子伦精品视手机观看| 日本一本久道| 麻豆AV久久AV盛宴AV| 中文字幕亚洲一区二区va| 色综合天天娱乐综合网| 波多野结衣侵犯蓝光| 怡红院Av一区二区| 国产精品亚洲一区欧美| 国产一区二区三区乱码在线观看| 精品视频一区二区三三区四区| 国产av国产v片大片线观看网站| 欧美日韩国产在线| 欧美亚洲日韩一区二区黄色| 天天看大片WWWWWWWW| a级免费的大片视频网| 亚洲欧美在线不卡| 国产av一区最新精品| 先锋影音中文字幕日韩欧美| 国产熟女强奸| 九九热在线免费| 狠狠干线上免费视频小说 | 国产成久久免费精品AV片天堂| 精品国产免费一区二区三区五区 | 久久免费视屏|